Skip to content
SolutionsApplicationsTechnologyEquipmentDownloads Contact Request a survey
Buried detection

SUB_Sense 2

Optical fiber below the ground

SUB_Sense 2 creates an invisible detection zone below the ground. It detects the weight of anyone walking over it, with nothing visible on the surface.

200 mfiber per zone
5–10 cmburial depth
0visible parts
pressure 5–10 cm
How it works

The operating principle.

The optical fiber is laid 5–10 cm below the surface, between two protective polyethylene meshes. A person’s weight presses on the mesh, the mesh presses on the fiber, and the analyzer raises the alarm.

The shape and size of each zone are defined at installation. A zone can follow the perimeter or cover a single spot: a door, a ramp, the area around a tank.

Small animals such as cats and small dogs exert less pressure. The threshold is set so that they are ignored.

Where it fits

Typical applications

  • High-security residences
  • Embassies and public buildings
  • Tanks and warehouses
  • Ramps, gates and entrances
  • Machinery safety zones
Benefits

What you get with SUB_Sense 2.

01

Invisible

It can’t be seen and doesn’t give away its position. An intruder doesn’t know where the zone begins.

02

Any soft ground

Lawn, soil, gravel, or under rugs and other surfaces.

03

Zone made to measure

Along the perimeter or at a single point, with a shape defined at installation.

04

No electronics in the ground

Only the fiber goes into the soil, with no circuits or power cables.

05

Worker safety

It can signal a person entering a hazardous machinery zone.

Technical data

Key specifications.

Full details in the datasheet.

Combine

SUB_Sense 2 closes the gaps a fence leaves open: gates, ramps, passages. Together with LINE_Fence 2 or FLEX_Sense 2 it adds a second line of detection inside the fence.

AnalyzerPQ1S 2 (1 zone) or PQ2S 2 (2 zones)
Fiber length per zoneup to 200 m, with margin for 2 splices
Burial depth5–10 cm
Protective layerpolyethylene, 1 m wide and multiples
Outputs1 per zone + 1 tamper, NO/NC relays
Power supply9–24 V DC, up to 100 mA
Analyzer protectionIP65
Operating temperature−40 to +85 °C (analyzer) · −35 to +80 °C (layer)
Documents

Brochures and datasheets.

All documents

Greek versions: Datasheet · Digital brochure · Print brochure

Important information. The performance of every system depends on the fence or structure it is fitted to, the site study, installation and maintenance. The system detects mechanical disturbance of the sensing assembly. Attempts that do not disturb it may not be detected. For higher requirements we recommend combining it with other measures, such as cameras or a second line of detection.
Site survey

Let’s look at your perimeter.

Send us the fence type and length. We’ll propose a solution and the number of zones, with a quote.